Descrizione del prodotto
E-Light IPL RF+ND YAG Laser Multifunction Beauty Machine
Model: HS-900
Advantages:
*8 handpieces for your option
*Multi Function Laser Platform
*Immediate and perfect results
*Safe and low-maintaining cost
*Long last & natural results
*Painless treatment
* Function choose independently
Product presentation of E-Light IPL RF+ND YAG Laser Multifunction Beauty Machine
The function of HS-900 Included as below:
1. IPL handpiece
ApplicationsPermanent Hair Removal, Photorejuvenation, Vascular Lesions, Pigment Lesions, Acne
Spectrum: 420-1200 nm
Filters: 420/510/560/610/640nm (Standard); 480/585/690/755 (Optional)
Energy Density (Fluence): 10-60 Level ( Max. 60J/cm² )
Pulse Duration: 2-20 ms
Pulse Delay: 5-50 ms
Pulse Characteristic: Multiple-Sequential Pulsing, Up to 15 Pulse
Repetition Rate: 1-4s
Spot Size: 12x35mm (Standard), 12x12mm, 12x50mm, 15x15mm, 15x35mm, 15x50mm(Optional)
Cooling: Continuos Contact Cooling
2. E-light (IPL with RF) handpiece
Applications Permanent Hair Removal, Photorejuvenation, Vascular Lesions, Pigment Lesions, Acne, Wrinkle
Spectrum: 420-1200 nm
Filters: 420/510/560/610/640nm (Standard); 480/585/690/755 (Optional)
Energy Density (Fluence): 10-60 Level ( Max. 60J/cm² )
RF Output Power: 200W
Pulse Duration: 2-20 ms
Pulse Delay: 5-50 ms
Pulse Characteristic: Multiple-Sequential Pulsing, Up to 15 Pulse
Repetition Rate: 1-4s
Spot Size: 12x35mm (Standard), 12x12mm, 12x50mm, 15x15mm, 15x35mm, 15x50mm (Optional)
Cooling: Continuos Contact Cooling
3. RF-Monopolar handpiece
Applications Skin Tightening, Sculpture, Pore Cantracting
RF Tip¢ 18mm, ¢ 28mm, ¢ 37mm
RF Frequency1MHz
RF Output Power200W
Cooling Continuos Contact Cooling
4. RF-Bipolar handpiece
Applications: Skin Tightening, Sculpture, Wrinkle Removal, Pore Shrink
RF Tip: ¢ 18mm, ¢ 28mm, ¢ 37mm
RF Frequency: 1MHz
RF Output Power: 200W
Cooling: Continuos Contact Cooling
5. Q-Switched ND: YAG Fractional Laser handpiece
Applications Pigmented Nevus, Birthmark, Cholasma, Macula, Telangietasia, Skin Rejuvenation
Spectrum: 1064nm /532nm
Energy: 600-1500mJ
Pulse Width: <10ns
YAG Bar: ¢ 6mm+¢ 7mm
Pulse Characteristic: Multiple-Sequential Pulsing
Repetition Rate: Up to 10 Hz
Spot Size: 1-8mm
6.2940nm Er: YAG Fractional Laser handpiece
Applications Wart and Nevus removal, Skin Resurfacing, Wrinkles and Fine lines, Photodamge, Texture Irregularity
Spectrum: 2940nm
Energy: 7x7 Pixel: 10-26mJ/microbeam; 9x9 Pixel: 5-15mJ/microbeam;
7.1540nm Er: Glass Fractional Laser handpiece
Applications: Skin resurfacing, Srugical scars, Strech marks, Acne Scar, Melasma, Whrinkle
Spectrum: 1540nm
Energy: 10x10 Pixel: 30-70mJ/microbeam; 18x18 Pixel: 5-25mJ/microbeam;
8. Long Pulse: ND: YAG 1064nm handpiece
Applications: Permanent Hair Removal for all skin types, Leg Veins, Vascular lesion, Wrinkle Removal
Spectrum: 1064nm
Energy Density (Fluence): ¢ 3mm Tip: 10-500J/cm² , ¢ 6mm Tip: 10-125J/cm² , ¢ 9mm Tip: 10-55J/cm²
Pulse Duration: 10-100ms
Pulse Characteristic: Multiple-Sequential Pulsing, 1-3 Pulse
Repetition Rate: Up to 1Hz
Spot Size: ¢ 3mm, ¢ 6mm, ¢ 9mm
Cooling: Continuos Contact Cooling
For more info. About our multifunction laser platfrom, pls contact me directly.
Best Regards,
Jennis Huang
( Export Department )
==============================================
SHANGHAI APOLO MEDICAL TECHNOLOGY CO., LTD
Add: 1~4/F, Builiding A, No. 388 Yindu Road, Xuhui District, Shanghai 200231, China
Tel: +86-21-34622842 ext. 8030
Fax: +86-21-34622840
E-Light IPL RF+ND YAG Laser Multifunction Beauty Machine
| Model | HS-900 |
| Power Supply | 100/110V or 230/260V, 50~60HZ |
| Dimension | 65cm *48cm *115cm( L*W*H) |
| Weight | 65kgs |
| Operate Interface | 8" Ture color touch screen TFT LCD |
| IPL | |
| Applications | Permanent Hair Removal, Photorejuvenation, Vascular Lesions, Pigment Lesions, Acne |
| Spectrum | 420-1200 nm |
| Filters | 420/510/560/610/640nm (Standard); 480/585/690/755 (Optional) |
| Energy Density (Fluence) | 10-60 Level ( Max. 60J/cm² ) |
| Pulse Duration | 2-20 ms |
| Pulse Delay | 5-50 ms |
| Pulse Characteristic | Multiple-Sequential Pulsing, Up to 15 Pulse |
| Repetition Rate | 1-4s |
| Spot Size | 12x35mm (Standard), 12x12mm, 12x50mm, 15x15mm, 15x35mm, 15x50mm(Optional) |
| Cooling | Continuos Contact Cooling |
| E-light (IPL with RF) | |
| Applications | Permanent Hair Removal, Photorejuvenation, Vascular Lesions, Pigment Lesions, Acne, Wrinkle |
| Spectrum | 420-1200 nm |
| Filters | 420/510/560/610/640nm (Standard); 480/585/690/755 (Optional) |
| Energy Density (Fluence) | 10-60 Level ( Max. 60J/cm² ) |
| RF Output Power | 200W |
| Pulse Duration | 2-20 ms |
| Pulse Delay | 5-50 ms |
| Pulse Characteristic | Multiple-Sequential Pulsing, Up to 15 Pulse |
| Repetition Rate | 1-4s |
| Spot Size | 12x35mm (Standard), 12x12mm, 12x50mm, 15x15mm, 15x35mm, 15x50mm (Optional) |
| Cooling | Continuos Contact Cooling |
| RF-Monopolar | |
| Applications | Skin Tightening, Sculpture, Pore Cantracting |
| RF Tip | ¢18mm, ¢28mm, ¢37mm |
| RF Frequency | 1MHz |
| RF Output Power | 200W |
| Cooling | Continuos Contact Cooling |
| RF-Bipolar | |
| Applications | Skin Tightening, Sculpture, Wrinkle Removal, Pore Shrink |
| RF Tip | ¢18mm, ¢28mm, ¢37mm |
| RF Frequency | 1MHz |
| RF Output Power | 200W |
| Cooling | Continuos Contact Cooling |
| Q-Switched ND:YAG Fractional Laser | |
| Applications | Pigmented Nevus, Birthmark, Cholasma, Macula, Telangietasia, Skin Rejuvenation |
| Spectrum | 1064nm /532nm |
| Energy | 600-1500mJ |
| Pulse Width | <10ns |
| YAG Bar | ¢6mm+¢7mm |
| Pulse Characteristic | Multiple-Sequential Pulsing |
| Repetition Rate | Up to 10 Hz |
| Spot Size | 1-8mm |
| 2940nm Er:YAG Fractional Laser | |
| Applications | Wart and Nevus removal, Skin Resurfacing, Wrinkles and Fine lines, Photodamge, Texture Irregularity |
| Spectrum | 2940nm |
| Energy | 7x7 Pixel: 10-26mJ/microbeam; 9x9 Pixel: 5-15mJ/microbeam; |
| 1540nm Er:Glass Fractional Laser | |
| Applications | Skin resurfacing, Srugical scars, Strech marks, Acne Scar, Melasma, Whrinkle |
| Spectrum | 1540nm |
| Energy | 10x10 Pixel: 30-70mJ/microbeam; 18x18 Pixel: 5-25mJ/microbeam; |
| Long Pulse ND:YAG 1064nm | |
| Applications | Permanent Hair Removal for all skin types, Leg Veins, Vascular lesion, Wrinkle Removal |
| Spectrum | 1064nm |
| Energy Density (Fluence) | ¢3mm Tip: 10-500J/cm², ¢6mm Tip: 10-125J/cm², ¢9mm Tip: 10-55J/cm² |
| Pulse Duration | 10-100ms |
| Pulse Characteristic | Multiple-Sequential Pulsing,1-3 Pulse |
| Repetition Rate | Up to 1Hz |
| Spot Size | ¢3mm, ¢6mm, ¢9mm |
| Cooling | Continuos Contact Cooling |